wellcome toFuzhou office Nets
Position:home>Office sector> Parameter of standard of office building of international first class, top class

Parameter of standard of office building of international first class, top class

From;  Author:Stand originally

Top class: Office part needs to exceed 50000 square metre

Attend " standard " the branch of Chengdu of limited company of service of property of international of the first peace and tranquility that makes the work tells a reporter about chief, situation of office building of top class business affairs wants the core section that focuses relatively in business affairs area.

Building: Its handle official bussiness to need to exceed 50000 square metre partly, every floor area must maintain in 1500-2000 square metre.

Structural frame: The big Tang Yingkuan of office building open, carry tall three-layer or above; Wear upland stage ≥ 15 centimeters; The layer clear height outside dividing platform reachs above 2.7 meters; The passageway is 2 meters wide reach above.

Jockey: By the edifice total floor area is calculated, every 150 square metre configure a parking space, on special ground, subterranean parking lot should be set automatic plan fee system and system of security of guard against theft.

Elevator: According to the edifice total floor area is calculated, every guest ladder serves an area not to exceed 4000 square metre; Await time to must not exceed 30 seconds; Customer money is detached, goods ladder at least two, advanced intelligence controls a system.

Security: "Property right is hired only do not make work, execute onefold property right. " introduce according to concerning chief, need to hour security personnel serves and 24 defend a service, and business affairs form a complete set. Top class office building still must have goods special passageway and disabled passageway, after building 1 to 2 years inside enter rate cannot under 70% .

First class: Elevator awaits time not to exceed 40 seconds

Building: Its handle official bussiness to should exceed 20000 square metre partly, every floor area not under 1000 square metre. 1-2 inside year enter rate not under 65% .

Elevator: Basis " standard " , the lift a person operating from within in coordination with outside forces of first class office building has high-grade adornment; By the edifice total floor area is calculated, every guest ladder serves an area not to exceed 5000 square metre; Await time not to exceed 40 seconds; Customer money is detached, goods ladder at least 1; Perfect and advanced intelligence controls a system.

Structural frame: The construction program of first class office building is big capacious, carry tall three-layer or above; Wear upland stage ≥ 15 centimeters; The layer clear height outside dividing platform is controlled for 2.7 meters.

Jockey: By the edifice total floor area is calculated, every 150-200 square metre configures a parking space; Deploy special ground to go up, subterranean parking lot; Subterranean parking lot should be set automatic plan fee system and system of security of guard against theft.